NetDrive 4 documentation

Help and Support

Step-by-step guides for NetDrive 4: install the app, connect your storage, and work with your files.

Common problems

Common problems

This page explains the messages you are most likely to see and what to do about them. For problems with a particular storage, see Synology, Google Drive, and FTP.

When you contact support, attach the log files. See Collect and send logs.

When NetDrive cannot reach its background service

NetDrive does its work through a background service that runs on your computer. If NetDrive cannot reach the service, the sign-in screen shows one of these messages instead of the sign-in fields:

  • The NetDrive service is not running, The NetDrive service is not responding, or Could not start the file system service, with "Could not connect to the background service. Please try again in a moment." Click Try again. If the message comes back, click Restart the background service on the same screen. See Restart the background service.
  • The NetDrive installation looks damaged: NetDrive could not find a part of its installation. Install NetDrive again. See Install and uninstall.
  • Please restart NetDrive: "The connection to the background service got stuck inside NetDrive. Quit NetDrive from its tray (menu bar) icon menu, then open it again. Closing the window does not quit the app."

Each of these messages has Open log folder, which shows the log files. Attach them when you contact support.

Restart the background service

Restarting the background service helps when mounting or unmounting stalls or stops responding, or when NetDrive says the service is not responding. You can restart it from three places:

  • Settings > Troubleshooting > Restart the background service: click Restart.
  • The sign-in screen, when NetDrive cannot reach the service: Restart the background service.
  • The Drives screen, when unmounting a drive takes long: Restart on the drive's row. See When unmounting takes long.

NetDrive first asks Restart the background service?. If drives are mounted, it says how many: they are all unmounted, and unsaved files may be lost. Save your work, and then click Restart.

On Windows, Windows then asks whether to allow the change. Click Yes.

NetDrive shows "Restarting the services…", restarts the service, and connects to it again in the same way as when it starts. Mount your drives again if you need them.

If the restart fails, the screen stays as it was. In Settings, one of these messages appears:

  • "Administrator rights are required — the elevation prompt was declined, so the background service was not restarted." Click Restart again and allow the change this time.
  • "Could not restart the background service." Try again. If it keeps happening, restart your computer.

When mounting fails

If a drive cannot be mounted, its row in Drives shows Failed, and the reason appears in red under the drive's name. See When mounting fails. Some reasons and what to do:

  • "Drive letter already used." (Windows): another drive already uses the drive letter you chose for this drive. In the drive menu, click Edit and choose another letter in Drive letter, or choose Auto to let NetDrive pick a free letter. See Mount options.
  • "No available drive letter." (Windows): all drive letters are in use. Unmount or disconnect a drive you don't need, and try again.
  • "The storage server's certificate could not be verified.": NetDrive could not trust the certificate of the server. If you know that your server uses a self-signed certificate, edit the drive and select Ignore certificate errors (self-signed certificate) in its storage form, and then connect again. The WebDAV form has this option; see WebDAV. If the certificate has expired or was issued for another server name, it must be fixed on the server. The same message can appear when you open the drive in Browse.
  • "Cache path error.": NetDrive cannot use its cache folder. Check Cache folder in Settings > Cache, and choose another folder if needed. See Settings.
  • "The service is still processing this drive, so the request was not accepted." or "No response from ndagent. Please try again in a moment.": wait a moment, and try again. If it keeps happening, restart the background service.
  • "The drive was not mounted. Try mounting again.": the row still shows the drive as Mounted. Click Unmount, and then Mount again.
  • "Mount failed (code -42).": the number is an error code. Tell it to our support team, and attach the drive's log. To get the log, click Log on the drive's row.
  • Something is already there (Mac): the drive's mount location is not empty. See When the mount location is in use.

If the drive's settings are wrong, for example the password or the server address, correct them with Edit. See Edit a drive.

When the Mac file system extension is not ready

To mount drives, NetDrive needs a file system extension on your Mac. Which one it uses depends on the Mac. Until it is ready, you can still open your files in Browse.

Apple Silicon Macs with macOS 26 or later

These Macs use Apple's FSKit, and the NetDrive extension must be turned on.

  • Enable File System Extension, or "The NetDrive file system extension is not enabled." under the drive: go to System Settings > General > Login Items & Extensions, switch to By Category, and click the ⓘ next to File System Extensions. Turn on NetDrive File System, and mount the drive again. Turning it on may not work from the By App view. See Install and uninstall.
  • File System Extension Not Installed: the extension is not registered with macOS. Install NetDrive again.

These messages also appear only on these Macs:

  • "macOS could not start the file system extension (extensionKit error 2). This can happen right after an update. Restart your Mac, then try again."
  • "The mount did not finish within 60 seconds. If this keeps happening after an update, restart your Mac and try again."
  • "macOS still holds a record of an earlier mount at this location (error 516). Restart your Mac, or rename the drive and try again." To rename the drive, use Edit in the drive menu.

Other Macs (Intel, or Apple Silicon with macOS 14 or 15)

These Macs use a kernel extension, which macOS must allow once. If you mount a drive before allowing it, NetDrive shows File system extension required.

  1. Click Open System Settings, or open System Settings > Privacy & Security.
  2. Allow the system software from 'Bdrive Inc.'.
  3. Restart your Mac.

If no allow option appears, your startup security settings are blocking kernel extensions. Click Enable System Extensions… on the same screen, follow the instructions, and then try again. See Install and uninstall.

Logs

NetDrive writes what it does to log files. They help our support team find the cause of a problem.

  • Settings > Logs > Open log folder shows the folder with the log files. The folder is C:\ProgramData\NetDrive3\nd3log on Windows and ~/Library/Logs/NetDrive3/nd3log on a Mac.
  • Log in the drive menu, or on the row of a drive that failed to mount, shows the log file of that drive.
  • Log level in Settings > Logs sets how much detail is written.

To collect the log files and send them to our support team, see Collect and send logs.